Toll Free: 800.618.2562 | Main: 936.539.5252

Edwards Liquid Ring Two-Stage Pumps for the Power Industry

Applications: Condenser Air Extraction / Waterbox Priming / Fly Ash | Manufacturer: Edwards

Edwards liquid ring vacuum pumps provide vacuum solutions for power industry applications, including condenser air extraction, waterbox priming, fly ash handling, and flue gas desulphurisation. Engineered around the requirements of thermal, nuclear, and solar-powered plants, these systems help remove air and non-condensable gases, support condenser performance, and provide robust vacuum pumping for critical power plant processes.

Product Specifications
Condenser Air Extraction
Two-Stage LR Packages (EHR2390–SHR23500)
CEP Package Sizes
CEP750-2 to CEP7500-2
Waterbox Priming
Single-Stage (EHR1190 / EHR1390)
Waterbox Capacity
180 to 440 m³/h
Fly Ash Handling
Up to 5,000 m³/h
SCP Pump Sizes
EHR2190 to SHR2750
SCP Configurations
Simplex, Duplex, Common Separator
Waterbox Motor Rating
5.5 to 15 kW

Liquid Ring Two-Stage Pump Design and Features

Two-stage liquid ring pump packages are used for condenser air extraction
Liquid ring pumps handle high vapour loads as vapour can condense at pump suction
Single-stage liquid ring pumps used for condenser waterbox priming
Total seal water recirculation systems available for waterbox priming
Vacuum receivers can include pressure transmitters for pump operation control
Automatic drain tank arrangements remove water carryover and prevent corrosion
Priming valves prevent vacuum system cycling and minimise cooling water carryover
Fly ash handling systems utilise stainless steel impellers with erosion-resistant materials
CEP packages provide fully automatic operation for larger steam turbine plants
CEP packages include dedicated seal water circuits and inlet water spray
Inter-stage anti-cavitation devices support CEP package operation
SCP packages provide manual operation for industrial installations
SCP systems available in simplex, duplex, and common configurations
Stainless steel plate-type heat exchangers in SCP seal water recirculation systems

Applications

Power Generation
Thermal Power Plants
Nuclear Power Plants
Solar-Powered Power Plants
Condenser Air Extraction
Condenser Waterbox Priming
Fly Ash Handling
Flue Gas Desulphurisation
Steam Turbine Condenser Systems

Power Industry Liquid Ring Pump Packages

Edwards offers two standard condenser air extraction package concepts for different power industry requirements.

Package Application / Configuration Key Features
CEP
SHR2400 – SHR23500
Larger steam turbine plants Fully automatic operation, dedicated seal water circuit, inlet water spray, inter-stage anti-cavitation device, recirculation pump, multiple level-control set points, discharge temperature monitoring, airflow measurement, and heat exchanger options
SCP
EHR2190 – SHR2750
Lower-capacity industrial and marine installations Manual operation, simplex/duplex/common configurations, seal water recirculation, inlet water spray, inter-stage anti-cavitation device, and plate-type heat exchanger

Waterbox Priming Systems

The Edwards waterbox priming system uses three main components: vacuum pumps, a vacuum receiver, and priming valves supplied according to customer requirements. Simplex, duplex, and common package arrangements are available. Duplex systems provide two liquid ring pumps with independent seal-water recirculation systems, while common configurations use two pumps with a combined recirculation system.

Custom Liquid Ring Two-Stage Vacuum Systems

For specialised power industry requirements, Edwards offers several non-standard system configurations:

Custom System Purpose / Application
Hybrid Air Ejector / Liquid Ring System Combines air ejector and liquid ring pump technology
Steam Ejector / Liquid Pump System Combines steam ejector and liquid pump technology
Large-Capacity Hogging System Single-stage system for air-cooled condensers
Stainless Steel Pump Construction Available for geothermal applications
Custom Seal Water Cooling Cooling system configured for specific requirements
Multiple Heat Exchangers Designed for applications using low-quality cooling water
Air-Blast Cooler Suitable where cooling water availability is limited

These configurations allow the liquid ring vacuum system to be adapted to specific power industry operating conditions and installation requirements.